Package | ihe.rad.imr |
Type | CapabilityStatement |
Id | Id |
FHIR Version | R4 |
Source | https://profiles.ihe.net/RAD/IMR/https://build.fhir.org/ig/IHE/RAD.IMR/CapabilityStatement-IHE.IMR.ReportRepository.html |
Url | https://profiles.ihe.net/RAD/IMR/CapabilityStatement/IHE.IMR.ReportRepository |
Version | 1.1.0 |
Status | active |
Date | 2022-02-20T00:00:00-05:00 |
Name | IHE_IMR_ReportRepository |
Title | Report Repository |
Experimental | False |
Realm | uv |
Authority | ihe |
Description | IHE Radiology Interactive Multimedia Report (IMR) - Report Repository |
Copyright | IHE http://www.ihe.net/Governance/#Intellectual_Property |
Kind | requirements |
No resources found
No resources found
Note: links and images are rebased to the (stated) source
{
"resourceType" : "CapabilityStatement",
"id" : "IHE.IMR.ReportRepository",
"text" : {
"status" : "additional",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\">\n\tThis Requirements CapabilityStatement describes the Report Repository.\n\t</div>"
},
"url" : "https://profiles.ihe.net/RAD/IMR/CapabilityStatement/IHE.IMR.ReportRepository",
"version" : "1.1.0",
"name" : "IHE_IMR_ReportRepository",
"title" : "Report Repository",
"status" : "active",
"experimental" : false,
"date" : "2022-02-20T00:00:00-05:00",
"publisher" : "IHE Radiology Technical Committee",
"contact" : [
{
"telecom" : [
{
"system" : "url",
"value" : "https://www.ihe.net/ihe_domains/radiology/"
}
]
},
{
"telecom" : [
{
"system" : "email",
"value" : "radiology@ihe.net"
}
]
},
{
"name" : "IHE Radiology Technical Committee",
"telecom" : [
{
"system" : "email",
"value" : "radiology@ihe.net"
}
]
}
],
"description" : "IHE Radiology Interactive Multimedia Report (IMR) - Report Repository",
"jurisdiction" : [
{
"coding" : [
{
"system" : "http://unstats.un.org/unsd/methods/m49/m49.htm",
"code" : "001"
}
]
}
],
"copyright" : "IHE http://www.ihe.net/Governance/#Intellectual_Property",
"kind" : "requirements",
"fhirVersion" : "4.0.0",
"format" : [
"application/fhir+xml",
"application/fhir+json"
],
"rest" : [
{
"mode" : "server",
"security" : {
"description" : "Recommend IUA or SMART"
},
"resource" : [
{
"type" : "DiagnosticReport",
"profile" : "https://profiles.ihe.net/RAD/IMR/StructureDefinition/imr/diagnosticreport",
"interaction" : [
{
"code" : "read"
},
{
"code" : "search-type"
}
],
"searchParam" : [
{
"name" : "_id",
"type" : "token",
"documentation" : "Logical id of this artifact"
},
{
"name" : "_lastupdated",
"type" : "date",
"documentation" : "When the resource version last changed"
},
{
"name" : "subject",
"type" : "reference",
"documentation" : "The patient subject to this report"
},
{
"name" : "basedOn",
"type" : "reference",
"documentation" : "The ServiceRequest (or other) referenced by this report"
},
{
"name" : "imagingStudy",
"type" : "reference",
"documentation" : "The ImagingStudy referenced by this report"
},
{
"name" : "status",
"type" : "token",
"documentation" : "The report status"
},
{
"name" : "category",
"type" : "token",
"documentation" : "The high level category of this report"
},
{
"name" : "code",
"type" : "token",
"documentation" : "The type of this report"
},
{
"name" : "resultsInterpreter",
"type" : "reference",
"documentation" : "The primary result interpreter of this report"
}
]
}
],
"interaction" : [
{
"code" : "transaction",
"documentation" : "https://profiles.ihe.net/RAD/IMR/StructureDefinition/imr-store-multimedia-report-bundle"
},
{
"code" : "search-system"
}
]
}
]
}
XIG built as of ??metadata-date??. Found ??metadata-resources?? resources in ??metadata-packages?? packages.